UCT 212 MTM 60 mm is a take-up bearing unit designed for shafts with a nominal diameter of 60 mm. Its typical construction includes a UC212 self-aligning insert ball bearing and a T-type take-up housing, allowing adjustable shaft positioning along guide rails. Used in belt and chain tensioning systems and adjustable shaft support assemblies. Exact housing dimensions and load ratings require MTM confirmation. Available through simmering.pl, a specialist B2B industrial supply platform, with worldwide shipping from stock in Poland.
|
Parameter |
Specification |
|---|---|
|
Brand |
MTM |
|
Full designation |
UCT 212 MTM |
|
Bearing unit type |
Take-up bearing unit |
|
Housing type |
T-type take-up housing |
|
Typical bearing insert |
UC212 |
|
Nominal shaft diameter |
60 mm |
|
Construction |
Self-aligning insert bearing in housing |
|
Rolling elements |
Balls |
|
Number of ball rows |
One |
|
Shaft locking method |
Typically grub screws / set screws |
|
Misalignment compensation |
Yes, within permissible limits |
|
Position adjustment |
Housing movement along guide rails |
|
Housing material |
Requires MTM confirmation |
|
Sealing arrangement |
Depends on bearing insert version |
|
Lubrication |
Depends on specific design |
|
Basic dynamic load rating (C) |
Requires MTM catalogue confirmation |
|
Basic static load rating (C0) |
Requires MTM catalogue confirmation |
|
Unit mass |
Requires MTM catalogue confirmation |
Technical note: The UCT212 designation identifies the bearing unit type and nominal bore diameter of 60 mm. Exact housing dimensions, sealing arrangements and construction materials must be confirmed against the specific MTM product documentation.
A typical UCT212 assembly consists of:
T-type take-up bearing housing.
UC212 self-aligning insert ball bearing.
Spherical outer surface of the bearing insert.
Extended inner ring.
Shaft locking components.
Bearing seals, depending on the insert version.
The spherical outer surface of the bearing insert allows limited compensation for initial angular misalignment between the shaft and housing.
The position of the complete unit is adjusted by moving the housing along appropriately designed guide rails.
The T-type housing is designed for installation in a guiding and adjustment mechanism.
Unlike conventional pillow block or flange housings, it allows the bearing unit to move along a defined path.
This movement enables the position of the supported shaft to be adjusted.
The standard UCT212 configuration typically incorporates a UC212 insert ball bearing.
This insert features an extended inner ring and a spherical outer surface.
The exact insert configuration supplied by MTM should be verified before specifying replacement components.
|
Designation element |
Meaning |
|---|---|
|
UC |
Insert ball bearing with extended inner ring |
|
T |
Take-up housing |
|
212 |
Bearing unit size corresponding to a 60 mm bore |
|
MTM |
Bearing brand |
For the standard bore code 12:
The designation UCT212 therefore identifies a take-up bearing unit designed for a nominal shaft diameter of 60 mm.
Standard UCT212 dimensions published by other bearing manufacturers provide a useful reference for identifying the housing series.
However, the following dimensions are reference values for the UCT212 series and have not been independently confirmed for the exact MTM version.
|
Parameter |
Reference dimension |
|---|---|
|
Bore diameter (d) |
60 mm |
|
Housing width (A) |
64 mm |
|
Guide slot width (A1) |
22 mm |
|
Housing dimension (A2) |
42 mm |
|
Housing height (H) |
146 mm |
|
Guide spacing (H1) |
130 mm |
|
Housing dimension (H2) |
102 mm |
|
Overall length (L) |
194 mm |
|
Distance to bearing centre (L1) |
119 mm |
|
Guide length (L3) |
102 mm |
|
Inner ring width (B) |
65.1 mm |
|
Distance (S) |
25.4 mm |
Before replacing a unit from another manufacturer, the MTM mounting drawing should be checked, particularly the guide dimensions, adjustment hole geometry and shaft centre position.
The typical UC212 insert is a single-row ball bearing primarily designed to accommodate radial loads.
It may also accommodate axial loads within limits determined by its construction and shaft locking arrangement.
Correct selection of UCT 212 MTM requires consideration of:
Radial loading.
Axial loading.
Shaft rotational speed.
Belt or chain tension.
Guide rail rigidity.
Frame stiffness.
Operating temperature.
Lubrication conditions.
Environmental contamination.
Permissible loads on the insert and housing.
The basic dynamic load rating C is used in rolling bearing fatigue life calculations.
The basic static load rating C0 is relevant when assessing the risk of permanent deformation at rolling contacts.
The exact ratings must be confirmed for the insert used in the MTM assembly.
Load ratings from SKF, NTN, FAG or other manufacturers should not automatically be assigned to UCT 212 MTM.
The principal function of the T-type housing is to allow the bearing unit to move along guide rails.
Moving the housing changes the position of the shaft axis, making it possible to adjust the tension of a belt, chain or conveyor component.
Correct adjustment requires:
Proper alignment of the guide rails.
Parallel positioning of the supported shafts.
Balanced adjustment of both shaft supports.
Appropriate belt or chain tension.
Secure locking of the adjustment mechanism.
Verification of bearing operating conditions after adjustment.
Important: UCT212 is a take-up bearing unit, not a complete tensioning mechanism. It requires a suitable frame, guide rails and adjustment components.
Typical UC212 bearing inserts incorporate seals designed to reduce the entry of contaminants into the rolling contact area.
Many take-up bearing unit designs also provide a relubrication facility.
For the exact UCT 212 MTM version, the following characteristics should be confirmed:
Seal design.
Lubricant type.
Lubricant quantity.
Presence of a grease fitting.
Relubrication capability.
Recommended maintenance intervals.
Permissible operating temperature.
Limiting rotational speed.
Grease lubrication is commonly used in housed insert ball bearing assemblies.
The appropriate grease and relubrication interval depend on the bearing construction, speed, loading and operating environment.
In conveyor and industrial tensioning systems, bearings may be exposed to dust, moisture and process contaminants.
The effectiveness of the sealing arrangement must be assessed according to the actual working conditions.
Not all bearing units designated UCT212 necessarily use identical sealing systems.
|
Bearing unit |
Construction |
Main difference |
|---|---|---|
|
UCT 212 MTM |
Take-up bearing unit, 60 mm bore |
Adjustable position along guide rails |
|
UCP 212 |
Pillow block bearing unit |
Base-mounted housing |
|
UCF 212 |
Square flange bearing unit |
Four-bolt flange mounting |
|
UCFL 212 |
Oval flange bearing unit |
Two-bolt flange mounting |
|
UC 212 |
Insert ball bearing |
Bearing insert without take-up housing |
These assemblies may use similarly designated bearing inserts but differ in housing construction and mounting arrangements.
They are not automatically interchangeable as complete bearing units.
UCT212 take-up bearing units may be used in appropriately designed:
Belt conveyor systems.
Chain conveyor systems.
Belt tensioning mechanisms.
Chain tensioning mechanisms.
Adjustable shaft support assemblies.
Industrial material handling equipment.
Machinery incorporating take-up guide rails.
These are general application areas for UCT-type bearing units, not a manufacturer-confirmed compatibility list for specific machines using UCT 212 MTM.
Before ordering or replacing the bearing unit, verify:
Nominal shaft diameter of 60 mm.
Guide rail dimensions.
Housing dimensions and geometry.
Adjustment hole dimensions and spacing.
Shaft centre position.
Shaft locking method.
Magnitude and direction of operating loads.
Required adjustment travel.
Lubrication conditions.
Seal configuration.
Operating temperature.
Rotational speed.
The UCT212 designation alone does not establish complete interchangeability between products from different manufacturers.
Even when two bearing units have the same nominal bore diameter, their housing dimensions and mounting details may differ.
The complete installation drawing should therefore be checked before substitution.
Replacement of the bearing insert requires verification of the insert's outer geometry, inner ring dimensions, locking arrangement and sealing design.
The UC212 designation should not be treated as sufficient confirmation of every technical characteristic.
During installation:
Inspect the shaft and guide rails.
Clean all mating surfaces.
Verify housing dimensional compatibility.
Position the bearing unit within the guide rails.
Install the bearing insert on the shaft.
Set the correct shaft position.
Secure the insert according to the manufacturer's instructions.
Adjust belt or chain tension.
Check shaft parallelism.
Verify free rotation.
Inspect the complete adjustment mechanism.
Monitor operating temperature, noise and vibration after commissioning.
The tightening torque for shaft locking screws must be obtained from the documentation for the specific MTM bearing insert.
The bearing housing must move correctly within the guide rails without binding.
Uneven adjustment of opposite shaft supports can introduce unwanted loading and reduce bearing service life.
Excessive belt or chain tension increases the radial load acting on the bearing insert.
Tension should be adjusted according to the requirements of the complete drive or conveyor system.
Excessive belt tension: Increases radial loading and may shorten bearing life.
Incorrect guide rail alignment: Can cause housing misalignment and uneven loading.
Improper shaft locking: May allow movement between the shaft and inner ring.
Insufficient lubrication: Accelerates wear of rolling elements and raceways.
Contamination: May damage seals, balls and raceways.
Housing overload: Can cause damage to the housing or adjustment mechanism.
Incorrect tension adjustment: May result in uneven shaft support and increased bearing loads.
UCT 212 MTM 60 mm
UCT212 MTM
MTM UCT212
UCT 212 Take-Up Bearing Unit
MTM UCT212 60 mm Take-Up Unit
UCT212 Self-Aligning Bearing Unit
UCT212 T-Type Bearing Housing Assembly
UCT 212 60 mm Bearing Unit
Zespół łożyskowy napinający UCT212
These alternative designations support product identification in industrial catalogues, technical search engines, ERP systems and procurement platforms.
What is the bore diameter of UCT 212 MTM?
The nominal bore diameter is 60 mm.
What does UCT212 mean?
UCT212 identifies a take-up bearing unit typically consisting of a UC212 insert ball bearing and a T-type take-up housing.
Is UCT 212 MTM a self-aligning bearing unit?
The typical UCT212 construction provides limited compensation for initial angular misalignment through the spherical outer surface of the bearing insert.
Can UCT212 be used for belt tensioning?
Yes. Its take-up housing allows shaft position adjustment within suitable guide rails.
Does UCT 212 MTM contain a UC212 bearing insert?
The standard UCT212 design typically incorporates a UC212 insert. The exact configuration supplied by MTM should be confirmed.
Is the UCT212 MTM housing made of cast iron?
UCT212 housings are commonly manufactured from cast iron, but the material of the specific MTM version requires confirmation.
Does UCT212 require lubrication?
Yes. Suitable lubrication must be maintained. Relubrication capability and recommended maintenance intervals depend on the specific construction.
Can UCT212 MTM be replaced with an SKF, NTN or FAG bearing unit?
Replacement compatibility must be verified by comparing housing dimensions, guide rail geometry, bearing insert specifications, load ratings and shaft locking arrangements.
UCT 212 MTM 60 mm is a take-up bearing unit designed for shafts with a nominal diameter of 60 mm. Its typical construction consists of a UC212 self-aligning insert ball bearing and a T-type housing that moves along guide rails. It is commonly used in adjustable shaft support and belt or chain tensioning systems. Exact MTM housing dimensions require confirmation.
UCT 212 MTM 60 mm Take-Up Bearing Unit is offered through simmering.pl, a specialist B2B industrial supply platform serving manufacturing companies, wholesale buyers, maintenance departments, engineers and industrial procurement teams.
The platform provides rolling bearings, housed bearing units, industrial sealing solutions and technical components.
Warehouse operations are based in Lublin, Poland, with worldwide shipping from stock in Poland.
Product identification is based on the MTM brand, UCT212 designation and nominal shaft diameter of 60 mm.